◆ DSP (Digital signal processors) control
◆ Active input power factor correction, input power factor> 0.99
◆ Three level inverter technology,lower harmonic,higher efficiency
◆ Wide input voltage range 90V~300V and frequency range 40~70Hz
◆ Generator compatible
◆ Long battery lifecycle, more than 2000
◆ Remote on off (ROO) function (optional)
◆ Cold start & Economic operation mode (ECO)
◆ 50Hz/60Hz Frequency auto sensing
◆ Frequency converter mode: 50Hz input / 60Hz output or 60Hz input / 50Hz output
◆ Li-ion battery provide up to 3x backup time, comparing with regular Lead-acid UPS product
◆ Dry contact interface for BMS dominant control
◆ Incorporated MODBUS (RS485) interface with BMS, to achieve precise battery information (voltage/soc/soh etc.)
◆ Li-ion Battery Charger : Constant current , constant voltage, floating, turn-off 4 state charger for Li-ion battery, open to customize the logical behavior for customer- specified battery pack
We were established in 2015 , have two producing bases , 5 production line and monthly produce about 80,000 pieces.
Our ODM & OEM production is strictly based on the IS09001 and service customers in need.
REO is a one top power solution provider and warmly welcome to be our distributor and partner
Tower Model |
Hero LV 1K |
Hero LV 1KL |
Hero LV 2K |
Hero LV 2KL |
Hero LV 3K |
Hero LV 3KL |
Rack Model |
Hero LV 1KR |
Hero LV 1KRL |
Hero LV 2KR |
Hero LV 2KRL |
Hero LV 3KR |
Hero LV 3KRL |
Capacity |
1KVA/900W |
2KVA/1.8KW |
3KVA/2.7KW |
|||
Phase |
Single phase input single phase output |
|||||
AC INPUT | ||||||
Wiring |
1 phase 3 wires ( L/N+PE) |
|||||
Rated Voltage |
110/115/120/127VAC |
|||||
Voltage Range |
Line-Neutral: 60~145VAC |
|||||
Frequency Range |
40Hz~70Hz |
|||||
Input Power Factor |
≥0.99 |
|||||
AC OUTPUT | ||||||
Wiring |
L/N+PE |
|||||
Output Voltage |
110/115/120/127VAC |
|||||
Voltage Regulation |
±1% |
|||||
Output Frequency |
50/60±4Hz (Sync mode) ; 50/60Hz±0.1% (Free run) |
|||||
Waveform |
Pure sine wave |
|||||
Distortion (THDV%) |
<2% (Linear Load) ; <8% (Non-Linear Load) |
|||||
Overload Capability |
100%~105% continuous; 60Sec.@105%~130% rated load; 10Sec.@130%~150% rated load; 0.3Sec.@>150% rated load. |
|||||
EFFICIENCY | ||||||
ECO Mode |
88% |
89% |
90% |
|||
Battery Mode |
86% |
87% |
88% |
|||
BATTERY & CHARGER | ||||||
Rated Battery Voltage |
48VDC (default for 15cell of LiFePO4 ) |
|||||
Battery Capacity |
600WH |
External battery depends |
1000WH |
External battery depends |
1000WH |
External battery depends |
Backup Time |
>40mins @ full load |
>30mins @ full load |
>20mins @ full load |
|||
Charging Current |
4A/8A |
|||||
Charging Voltage |
52.8V(default for 15cell of LiFePO4 ) / customized according to battery request |
|||||
Charger Behavior & Protection |
CC. CV. floating. turn-off 4 states |
|||||
HMI | ||||||
LED Display |
Mains / battery status, load level, battery level, operation mode |
|||||
LCD Display with LED Indicator |
Input mains voltage, frequency, load level, operation mode, health status |
|||||
Standards Communication Interface | (1) RS232 port (2) Network card: support SNMP, TCP/IP protocol , for remote monitor the UPS via smart phone APP, web page, PC monitor software, support server/NAS shutdown (3) Dry contact interface for BMS control (4) MODBUS For BMS interface |
|||||
ENVIRONMENT | ||||||
Temperature Range |
-10~50oC |
|||||
Relative Humidity |
0-98%(Non-condensing) |
|||||
Acoustics Noise |
<55dB @ 1 meters |
|||||
PHYSICAL | ||||||
Tower Dimension WxDxH (mm) |
1K: 190x378x318 |
2K: 190x427x318 |
3K: 190x427x318 |
|||
1KL: 145x397x220 |
2KL: 145x397x220 |
3KL: 190x378x318 |
||||
Rack Dimension WxDxH (mm) |
1KR: 438x360x88 (2U) |
2KR: 438x500x88 (2U) |
3KR: 438x650x88 (2U) |
|||
1KRL: 438x360x88 (2U) |
2KRL: 438x360x88 (2U) |
3KRL: 438x360x88 (2U) |
||||
Tower N.W (kg) |
10.8 |
5 |
16.5 |
5.5 |
18 |
7.9 |
Rack N.W (kg) |
12.5 |
6.5 |
21.6 |
6.8 |
24.5 |
8.2 |
Tower Model |
Hero LV 6KL |
Hero LV 10KL |
Rack Model |
Hero LV 6KRL |
Hero LV 10KRL |
Capacity |
6KVA/5.4KW |
10KVA/9KW |
AC INPUT | ||
Input System |
Single phase (L/N+PE) |
|
Nominal Voltage |
100/110/120/127VAC |
|
Frequency |
50/60Hz |
|
Voltage Range |
60-145Vac±3VAC |
|
Frequency Range |
(40~70)±0.5Hz |
|
Input Power Factor |
>0.99 |
|
Bypass Voltage Range |
80~140VAC×(1±3%) |
|
BATTERY INPUT | ||
Charging Voltage |
216V(default for 60cell of LiFePO4 ) / Customized according to battery request |
|
Battery Capacity |
External |
|
Charger Behavior & Protection |
CC. CV. floating. turn-off 4 states |
|
Charging Current |
Long backup time model : 4A / 8A (optional) |
|
AC OUTPUT | ||
Output Wiring System |
Single phase (L/N+PE) |
|
Inverter Output Voltage |
100/110/120/127VAC ± 2% |
|
Waveform |
Pure sine wave |
|
Harmonic Distortion |
THD<2% (linear load) ; THD<7% (non-linear load) |
|
Output Frequency |
50/60±4Hz (Sync mode) |
|
Overload Capability |
105~125%≥ 60s; 126~150%≥30s, The recover point is 70%. |
|
Transfer Time |
Line mode <-> Battery mode : 0ms |
|
EFFICIENCY | ||
Line Mode |
>92% |
>93% |
Battery Mode |
>90% |
|
OTHERS | ||
Standards Communication Interface | (1) RS232 port (2) Network card: support SNMP, TCP/IP protocol , for remote monitor the UPS via smart phone APP, web page, PC monitor software, support server/NAS shutdown (3) Dry contact interface for BMS control (4) MODBUS For BMS interface |
|
Alarm Function |
AC/DC input under abnormal, overload condition and inverter problems |
|
Protection Function |
AC input or output above or below the range of voltage, overload, over temperature and short circuit protection |
|
ENVIRONMENT | ||
Temperature Range |
-10~50oC |
|
Relative Humidity |
0-98%(Non-condensing) |
|
Acoustics Noise |
<55dB @ 1 meters |
|
PHYSICAL | ||
Tower Dimension WxDxH (mm) |
190x546x340 |
239x555x528 |
Rack Dimension WxDxH (mm) |
438x500x88 (2U) |
438x530x176 (4U) |
Tower N.W (kg) |
16 |
26.1 |
Rack N.W (kg) |
15 |
26.1 |
Product specifications are subject to change without prior notice.