◆ The rack modular, hot-swapping, online double conversion
◆ High performance and efficiency, input PF>0.99, THDi<3%, efficiency >96%.
◆ Intelligent system self-diagnosis scheme, large capacity of history record storage space
◆ Redundancy fan design in power module, increasing the system reliability and tolerance.
◆ Top/bottom cable entry, flexible for different field installation.
◆ Easy for power expansion, installation and maintenance.
We were established in 2015 , have two producing bases , 5 production line and monthly produce about 80,000 pieces.
Our ODM & OEM production is strictly based on the IS09001 and service customers in need.
REO is a one top power solution provider and warmly welcome to be our distributor and partner
Model | M030/15 | M040/20 | M060/15 | M080/20 | M090/15 | M120/20 |
Capacity | 30KVA/30KW | 40KVA/40KW | 60KVA/60KW | 80KVA/80KW | 90KVA/90KW | 120KVA/120KW |
Phase | Three phase input and Three phase output | |||||
Main Input | ||||||
Input | 3P5W (3P+N+PE) | |||||
Rate Voltage | 380/400/415VAC(L-L) ; 220/230/240VAC(L-N) | |||||
Rate Freq. | 50/60Hz | |||||
Input PF | >0.99 | |||||
Current distortion | THDi<3%(100% Linear load) | |||||
Voltage range | 304~478VAC(L-L)full load; 304~228VAC (L-L) power derate from 100% to 75% | |||||
Freq. range | 40~70Hz | |||||
Battery | ||||||
Rate voltage | ±240VDC | |||||
Charging capacity | 20%*Output Capacity | |||||
Charging accuracy | ±1% | |||||
Bypass | ||||||
Rate voltage | 380/400/415VAC(L-L) ; 220/230/240VAC(L-N) | |||||
Voltage range | Range: -40%- +25% , Settable, default -20% ~ +15% | |||||
Overload | 110%, long time operation;110%< load<125%, 5 mins; 125%<load<150%,1 min;>150%,1 second | |||||
Inverter | ||||||
Rate voltage | 380/400/415VAC(L-L) 220/230/240VAC(L-N) | |||||
Rate Freq. | 50/60Hz | |||||
Output PF | 1 | |||||
Voltage accuracy | ±1.0% | |||||
Load response | <5% (20% – 80% -20% step load) | |||||
Recovery time | < 20ms (0% – 100% -0% step load) | |||||
Output THDu | <1%(linear load); <5% (non-linear load according to IEC 62040-3) | |||||
Overload | 110%,1 hour ; 125%,10 mins ; 150%,1 min ; >150%,200ms | |||||
Frequency accuracy | 0.1% | |||||
Synchronize window | Settable ±0.5Hz-±5Hz ; default ±3Hz | |||||
Slew rate | Settable 0.5Hz/S-3Hz/S ; default 0.5Hz/S | |||||
Phase Accuracy | 120°±0.5° | |||||
System | ||||||
Efficiency | Normal Mode ≥96% ; Battery Mode≥ 96% | |||||
Display | LED + 7 inch touch LCD | |||||
Certification- Safety | IEC62040-1, IEC60950-1 | |||||
Certification- EMS | IEC62040-2 IEC61000-4-2(ESD) IEC61000-4-3(RS) IEC61000-4-4 (EFT) IEC61000-4-5 (Surge) | |||||
IP degree | IP20 | |||||
Configuration | USB, RS232, RS485, Dry contact, Cold start | |||||
Option | SNMP card, AS400 card, Parallel kit, LBS, Air filter | |||||
Environment | 0-40℃ (operation) ; -25~70℃ (storage) ; 0-95% (Humidity, non-condensing) | |||||
Noise(dB)(1 meter) | 65dB @ 100% load, 62dB @ 45% load | |||||
Dimention | ||||||
Cabinet(W*D*H)mm | 482*700*396 (9U wheels not included) | 482*700*662 (15U wheels not included) | 482*700*840 (19U wheels not included) | |||
Module(W*D*H)mm | 440*555*85 2U |
Product specifications are subject to change without prior notice.