◆ DSP (Digital signal processors) njikwa
◆ Ndozi ihe ntinye ike na-arụ ọrụ, ihe ntinye ike> 0.99
◆ Teknụzụ inverter ọkwa atọ, harmonic dị ala, arụmọrụ dị elu
◆ Wide input voltaji nso 90V ~ 300V na ugboro nso 40 ~ 70Hz
◆ Generator dakọtara
◆ Ogologo ndụ batrị, karịa 2000
◆ Ọrụ ịgbanyụ anya (ROO) (nhọrọ)
◆ mmalite oyi & ọnọdụ ọrụ akụ na ụba (ECO)
◆ 50Hz/60Hz ugboro akpaaka
◆ Ọnọdụ ntụgharị ugboro ugboro: ntinye 50Hz / mmepụta 60Hz ma ọ bụ ntinye 60Hz / 50Hz
◆ Batrị Li-ion na-enye ihe ruru 3x ndabere oge, atụnyere ngwaahịa UPS Lead-acid mgbe niile.
◆ Ngwa kọntaktị akọrọ maka njikwa BMS kachasị
◆ Incorporated MODBUS (RS485) interface na BMS, iji nweta ozi batrị ziri ezi (voltaji/soc/soh wdg)
Chaja batrị Li-ion: chaja na-adịgide adịgide, voltaji mgbe niile, na-ese n'elu mmiri, gbanyụọ chaja steeti 4 maka batrị Li-ion, mepee iji hazie omume ezi uche dị na ya maka mkpọ batrị akọwapụtara nke ndị ahịa.
Anyị e guzobere na 2015 , nwere abụọ na-emepụta bases, 5 mmepụta akara na kwa ọnwa na-emepụta banyere 80,000 iberibe.
Ihe nrụpụta ODM & OEM dabere na IS09001 yana ndị ahịa ọrụ chọrọ.
REO bụ onye na-eweta ihe ngwọta ike kachasị elu ma jiri obi ụtọ nabata ịbụ onye nkesa na onye mmekọ anyị
Ụdị Tower | dike 1K | dike 1KL | dike 2K | dike 2KL | dike 3K | dike 3KL |
Ihe Nlereanya Rack | dike 1KR | dike 1KRL | dike 2KR | dike 2KRL | dike 3KR | dike 3KRL |
Ike | 1KVA/900W | 2KVA / 1.8KW | 3KVA / 2.7KW | |||
Usoro | Ntinye ntinye otu nkeji otu mmepụta otu nkeji | |||||
Ntinye AC | ||||||
Wiring | L/N+PE | |||||
Ogo voltaji | 208/220/230/240VAC | |||||
Oke voltaji | 90 ~ 300VAC | |||||
Oke ugboro ugboro | 40Hz ~ 70Hz | |||||
Ihe ntinye ike | ≥0.99 | |||||
Mpụta AC | ||||||
Wiring | L/N+PE | |||||
Voltaji mmepụta | 208/220/230/240VAC | |||||
Ụkpụrụ voltaji | ±1% | |||||
Ugboro mmepụta | 50/60± 4Hz (ọnọdụ mmekọrịta);50/60Hz± 0.1% (agba ọsọ efu) | |||||
Waveform | Sine ife dị ọcha | |||||
Mgbagha (THDV%) | <2%( Ibu ahịrị) ;<8% | |||||
Ibu Ibu Ike | 100% ~ 105% na-aga n'ihu ; 60Sec.@105% ~ 130% ibu e gosiri; 10Sec.@130%~150% gosiri ibu; 0.3Sec.@>150% gosiri ibu. | |||||
Ịrụ arụ ọrụ | ||||||
Ụdị ECO | 88% | 89% | 90% | |||
Ụdị batrị | 86% | 87% | 88% | |||
Batrị & chaja | ||||||
Voltaji batrị akwadoro | 48VDC (ndabara maka 15cell nke LiFePO4) | |||||
Ike batrị | 600WH | Batrị mpụga dabere | 1000WH | Batrị mpụga dabere | 1000WH | Batrị mpụga dabere |
Oge ndabere | > 40mins @ ibu zuru oke | >30mins @ ibu zuru oke | >20mins @ ibu zuru oke | |||
Ịchaji ugbu a | 4A/8A | |||||
Ịchaji voltaji | 52.8V (ndabara maka 15cell nke LiFePO4) / ahaziri dị ka arịrịọ batrị si dị | |||||
Omume chaja & Nchekwa | CC.CV.na-ese n'elu mmiri.gbanyụọ 4 steeti | |||||
HMI | ||||||
Ngosipụta LED | Ọkwa batrị / batrị, ọkwa ibu, ọkwa batrị, ọnọdụ ọrụ | |||||
Ngosipụta LCD nwere ihe ngosi LED | Ntinye voltaji mains, ugboro, ọkwa ibu, ọnọdụ ọrụ, ọnọdụ ahụike | |||||
Interface nkwurịta okwu ụkpụrụ | (1) ọdụ ụgbọ mmiri RS232 (2) Kaadị netwọkụ: na-akwado SNMP, TCP/IP protocol, maka anya nyochaa UPS site na smart ekwentị APP, ibe weebụ, PC nyochaa software, nkwado ihe nkesa / NAS nkwụsị. (3) interface kọntaktị akọrọ maka njikwa BMS (4) MODBUS Maka interface BMS | |||||
ENVIRONMNET | ||||||
Oke okpomọkụ | -10-50oC | |||||
Iru mmiri dị n'etiti | 0-98% (na-abụghị condensing) | |||||
Acoustics Noise | <55dB @ 1 mita | |||||
Anụ ahụ | ||||||
Ụlọ elu Dimension WxDxH (mm) | 1K: 190x378x318 | 2K: 190x427x318 | 3K: 190x427x318 | |||
1KL: 145x397x220 | 2KL: 145x397x220 | 3KL: 190x378x318 | ||||
Akụkụ Rack WxDxH (mm) | 1KR: 438x360x88 (2U) | 2KR: 438x500x88 (2U) | 3KR: 438x650x88 (2U) | |||
1KRL: 438x360x88 (2U) | 2KRL: 438x360x88 (2U) | 3KRL: 438x360x88 (2U) | ||||
Ụlọ elu NW (kg) | 10.8 | 5 | 16.5 | 5.5 | 18 | 7.9 |
Rack NW (kg) | 12.5 | 6.5 | 21.6 | 6.8 | 24.5 | 8.2 |
Nkọwapụta ngwaahịa nwere ike ịgbanwe na-enweghị ọkwa mbụ.
Ụdị Tower | dike 6KL | dike 10KL |
Ihe Nlereanya Rack | dike 6KRL | dike 10KRL |
Ike | 6KVA / 5.4KW | 10KVA/9KW |
Ntinye AC | ||
Sistemụ ntinye | Otu nkeji (L/N+PE) | |
Voltaji ọnụ | 208/220/230/240VAC | |
Ugboro ugboro | 50/60Hz | |
Oke voltaji | 90 ~ 300VAC | |
Oke ugboro ugboro | (40 ~ 70) ± 0.5Hz | |
Ihe ntinye ike | > 0.99 | |
Ntinye batrị | ||
Ịchaji voltaji | 216V (ndabara maka 60cell nke LiFePO4) / ahaziri dị ka arịrịọ batrị si dị | |
Ike batrị | Mpụga | |
Omume chaja & Nchekwa | CC.CV.na-ese n'elu mmiri.gbanyụọ 4 steeti | |
Ịchaji ugbu a | Ụdị oge ndabere ogologo: 4A/8A (nhọrọ) | |
Mpụta AC | ||
Sistemụ Wiring mmepụta | Otu nkeji (L/N+PE) | |
Voltaji mmepụta ihe ntụgharị | 208/220/230/240VAC± 1% | |
Waveform | Sine ife dị ọcha | |
Harmonic Distortion | THD <2% (ibu linear);THD <7% (ibu anaghị akwụ ụgwọ) | |
Ugboro mmepụta | 50/60± 4Hz (Ụdị mmekọrịta) | |
Ibu Ibu Ike | 100% ~ 105% na-aga n'ihu;60Sec.@105% ~ 130% ibu e gosiri; | |
Oge mbufe | Ụdị ahịrị <-> Ụdị batrị: 0ms | |
Ịrụ arụ ọrụ | ||
Ụdị ahịrị | > 92% | > 93% |
Ụdị batrị | > 90% | |
Ndị ọzọ | ||
Interface nkwurịta okwu ụkpụrụ | (1) ọdụ ụgbọ mmiri RS232 (2) Kaadị netwọkụ: Nkwado SNMP, TCP/IP protocol, maka ime nyochaa UPS site na smart ekwentị APP, ibe weebụ, PC nyochaa software, nkwado ihe nkesa / NAS nkwụsị. (3) interface kọntaktị akọrọ maka njikwa BMS (4) MODBUS maka interface BMS | |
Ọrụ mkpu | Ntinye AC/DC n'okpuru ọnọdụ adịghị mma, oke ibu na nsogbu inverter | |
Ọrụ nchekwa | Ntinye AC ma ọ bụ mmepụta n'elu ma ọ bụ n'okpuru oke voltaji, oke ibu, karịa okpomọkụ na nchebe sekit dị mkpụmkpụ | |
Gburugburugburu | ||
Oke okpomọkụ | -10-50oC | |
Iru mmiri dị n'etiti | 0-98% (na-abụghị condensing) | |
Acoustics Noise | <55dB @ 1 mita | |
Anụ ahụ | ||
Ụlọ elu Dimension WxDxH (mm) | 190x378x318 | 190x546x340 |
Akụkụ Rack WxDxH (mm) | 438x500x88(2U) | 438x500x88(2U) |
Ụlọ elu NW (kg) | 14.8 | 16 |
Rack NW (kg) | 11.5 | 13.5 |
Nkọwapụta ngwaahịa nwere ike ịgbanwe na-enweghị ọkwa mbụ.